Quick Navigation

Topics

Spin Qubits Silicon Quantum Computing Quantum Chemistry Quantum Simulation

Accuracy verification of protoacoustic measurements in a heterogeneous phantom by an optical hydrophone.

PubMed
Authors: Chen Y, Kasamatsu K, Kuriyama Y, Uesugi T, Ishi Y, Murakami T, Hidani S, Caulfield M, Unlu MB, Rohringer W, Matsuura T

Year

2025

Paper ID

9541

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

291

Citations

1

Abstract

BACKGROUND: Protoacoustics has emerged as a promising real-time range measurement method for proton therapy. Optical hydrophones (OHs) are considered suitable to detect protoacoustic waves owing to their ultracompact size and high sensitivity. In our previous research, we demonstrated that the time-of-arrival (TOA) measured by an OH showed good agreement with the simulated ground truth in a homogeneous medium. PURPOSE: The purpose of the study was to experimentally evaluate the accuracy of the TOA and compression peak pressures detected by the OH. Protoacoustic waves that undergo the typical distortions occurring in the human body were investigated. In such cases, the use of small detectors such as OHs is desirable to minimize the effects of detector size and directivity. METHODS: A 100-MeV proton pencil beam emitted from a fixed-field alternating gradient accelerator was irradiated onto a homogeneous water phantom and a water phantom with a half- or full-sized silicone plate downstream of the Bragg peak (BP) or a bone plate that covered half of the beam cross-section in the beam path. The OH was shifted 70 mm laterally across the beam axis downstream of the BP to measure the protoacoustic waves. The k-WAVE acoustic wave transport simulation was employed as the ground truth. The TOA and the first compression peak pressures were compared between the simulation and experiment. RESULTS: The TOA deviation against the ground truth was primarily attributed to alignment errors of the measurement devices and phantoms, with deviations of < 1 mm. The peak pressure distribution closely resembled the ground truth, with FWHM differences of 0.0%-3.0% for the tested geometries. CONCLUSION: The OH was able to determine the TOA and peak pressures with sufficient accuracy in heterogeneous phantoms, even without considering the effect of the size of the detector or directivity on the measurements.

Why This Paper Matters

  • This paper contributes to the Quantum Simulation research area in the Quantum Articles archive.
  • It adds a 2025 reference point for readers tracking recent quantum research.
  • BACKGROUND: Protoacoustics has emerged as a promising real-time range measurement method for proton therapy.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #9541 #68971 On solutions of the Schrödinger... #69042 Simultaneous Fragment Docking f... #69041 Multi-modes Bessel-Gaussian-Orb... #69040 Collective Emission in LH2 Asse...

External citation index: OpenAlex citation signal • updated 2026-06-13 18:38:32

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.