Quick Navigation

Topics

Quantum State Preparation Representation Quantum Chemistry Quantum Simulation Entanglement Theory Quantum Correlations

Directional vector-based quick evaluation method for protective plate effects in X-ray fluoroscopy (DQPEX).

PubMed
Authors: Hizukuri K, Fujibuchi T, Han D, Arakawa H, Furuta T

Year

2025

Paper ID

9523

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

246

Citations

4

Abstract

One radiation protection measure for medical personnel in X-ray fluoroscopy is using radiation protective plates. A real-time interactive tool visualizing radiation-dose distribution varied with the protective plate position will help greatly to train medical personnel to protect themselves from unnecessary radiation exposure. Monte Carlo simulation can calculate the individual interactions between radiations and objects in the X-ray room, and reproduce the complex dose distribution inside the room. However, Monte Carlo simulation is computationally time-consuming and not suited for real-time feedback. Therefore, we developed a new method to calculate the dose distribution with the presence of protective plates instantly using pre-computed directional vectors, named Directional vector-based Quick evaluation method for Protective plates Effects in X-ray fluoroscopy (DQPEX). DQPEX uses a database of dose distributions and directional vectors precomputed by Monte Carlo code, Particle and Heavy Ion Transport code System (PHITS). Assuming the dose at each position was all contributed from radiations in the direction indicated by the directional vector, the dose reduction by the protective plates at the position was determined whether the backtrace line of the directional vector has a intersect with the protective plate or not. With DQPEX, the whole dose distribution in X-ray room with the presence of a protective plate can be computed about 13 s, which is approximately 1/6000 of the full PHITS simulation. Sufficient accuracy of DQPEX to visualize the effect of a protective plate was confirmed by comparing the obtained dose distribution with those obtained by the full PHITS simulation and measurements.

Why This Paper Matters

  • This paper contributes to the Quantum Simulation research area in the Quantum Articles archive.
  • It adds a 2025 reference point for readers tracking recent quantum research.
  • One radiation protection measure for medical personnel in X-ray fluoroscopy is using radiation protective plates.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #9523 #78797 Local polarization control of o... #78792 Demonstration of subspace-searc... #78846 Analog quantum simulation of Sh... #78837 TLS loss in superconducting res...

External citation index: OpenAlex citation signal • updated 2026-10-22 06:32:34

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.