Quick Navigation
Topics
Superconducting Qubits
Quantum Compilation Routing Architecture
Quantum Control Electronics System Integration
Quantum Chemistry
The detective quantum efficiency of cadmium telluride photon‐counting x‐ray detectors in breast imaging applications
Crossref
Authors: James A. Day, Jesse Tanguay
Year
2021
Paper ID
5259
Status
Peer-reviewed
Abstract Read
~2 min
Abstract Words
350
Citations
N/A
Abstract
AbstractPurposeIn breast imaging applications, cadmium telluride (CdTe) photon counting x‐ray detectors (PCDs) may reduce radiation dose and enable single‐shot multi‐energy x‐ray imaging. The purpose of this work is to determine the upper limits of the detective quantum efficiency (DQE) of CdTe PCDs for x‐ray mammography and to compare them with the published DQEs of energy‐integrating detectors (EIDs) and other PCDs.MethodsWe calibrated and validated a Monte Carlo (MC) model of the DQE of CdTe PCDs using an XCounter CdTe PCD. Our model accounted for charge sharing, electronic noise, and charge summation logic. We used a 28 kVp Mo/Mo spectrum hardened by 3.9 cm of Lucite to optimize the detector thickness and energy threshold for pixel sizes of 50, 85, and 100 m with and without inter‐pixel charge summation logic. The figure of merit used for optimization was the integral of the DQE, which is equivalent to the detectability index for a delta function task function, which represents a high‐frequency task.ResultsFor an electronic noise level equal to that of the XCounter, the optimal DQE(0) without charge summing was 0.74. Charge summing for charge‐sharing correction reduced DQE(0) by 14% due to an increase in electronic noise. Reducing the electronic noise to ∼0.5 keV per pixel in combination with charge summing resulted in DQE(0) 0.78 for 85 m pixels, which is approximately equal to that of a‐Se and slot‐scanning silicon‐strip PCDs. At higher spatial frequencies, and for matched pixel sizes, the DQE was inferior to that of a‐Se EIDs and superior to that of slot‐scanning silicon‐strip PCDs in the scan direction but inferior in the slit direction.Conclusions(1) CdTe PCDs have the potential to provide a zero‐frequency DQE equal to that of a‐Se EIDs and slot‐scanning silicon‐strip PCDs, but this will require electronic noise levels ∼0.5 keV per pixel. (2) At mid‐to‐high spatial frequencies the DQE of CdTe PCDs may be (a) inferior to that of a‐Se EIDs and slot‐scanning silicon‐strip PCDs in the slit direction, and (b) superior to slot‐scanning silicon‐strip PCDs in the scan direction.
Why This Paper Matters
- This paper contributes to the Quantum Chemistry research area in the Quantum Articles archive.
- It adds a 2021 reference point for readers tracking recent quantum research.
- AbstractPurposeIn breast imaging applications, cadmium telluride (CdTe) photon counting x‐ray detectors (PCDs) may reduce radiation dose and enable single‐shot multi‐energy...
Paper Tools
Become a member to use research tools
Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.
Show Paper Publisher Share
Cite This Paper
Copy URL
Compare
Copy DOI Add to Reading List
Category Correction Request
Category Correction Request
Help us improve classification quality by proposing a better category. Every request is reviewed by an admin.
Sign in to submit a category correction request for this paper.
Log In to SubmitReferences & Citation Signals
Community Reactions
Quick sentiment from readers on this paper.
Score:
0
Likes: 0
Dislikes: 0
Sign in to react to this paper.
Discussion & Reviews (Moderated)
Average Rating: 0.0 / 5 (0 ratings)
No written reviews yet.