Quick Navigation

Topics

Photonic Quantum Computing Quantum Simulation Quantum Chemistry

Implementation of a Large-Area Diffractive Lens Using Multiple Sub-Aperture Diffractive Lenses and Computational Reconstruction

Crossref
Authors: Shivasubramanian Gopinath, Praveen Periysamy Angamuthu, Tauno Kahro, Andrei Bleahu, Francis Gracy Arockiaraj, Daniel Smith, Soon Hock Ng, Saulius Juodkazis, Kaupo Kukli, Aile Tamm, Vijayakumar Anand

Year

2022

Paper ID

13622

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

232

Citations

15

Abstract

Direct imaging systems that create an image of an object directly on the sensor in a single step are prone to many constraints, as a perfect image is required to be recorded within this step. In designing high resolution direct imaging systems with a diffractive lens, the outermost zone width either reaches the lithography limit or the diffraction limit itself, imposing challenges in fabrication. However, if the imaging mode is switched to an indirect one consisting of multiple steps to complete imaging, then different possibilities open. One such method is the widely used indirect imaging method with Golay configuration telescopes. In this study, a Golay-like configuration has been adapted to realize a large-area diffractive lens with three sub-aperture diffractive lenses. The sub-aperture diffractive lenses are not required to collect light and focus them to a single point as in a direct imaging system, but to focus independently on different points within the sensor area. This approach of a Large-Area Diffractive lens with Integrated Sub-Apertures (LADISA) relaxes the fabrication constraints and allows the sub-aperture diffractive elements to have a larger outermost zone width and a smaller area. The diffractive sub-apertures were manufactured using photolithography. The fabricated diffractive element was implemented in indirect imaging mode using non-linear reconstruction and the Lucy–Richardson–Rosen algorithm with synthesized point spread functions. The computational optical experiments revealed improved optical and computational imaging resolutions compared to previous studies.

Why This Paper Matters

  • This paper contributes to the Quantum Simulation research area in the Quantum Articles archive.
  • It adds a 2022 reference point for readers tracking recent quantum research.
  • Direct imaging systems that create an image of an object directly on the sensor in a single step are prone to many constraints, as a perfect image is required to be recorded...

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #13622 #78797 Local polarization control of o... #78792 Demonstration of subspace-searc... #78846 Analog quantum simulation of Sh... #78837 TLS loss in superconducting res...

External citation index: OpenAlex citation signal • updated 2026-10-23 06:55:03

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.