Quick Navigation
Topics
Quantum Chemistry
Quantum Simulation
Simulation studies of optimum energies for DXA: dependence on tissue type, patient size and dose model.
PubMed
Authors: Michael GJ, Henderson CJ
Year
1999
Paper ID
13364
Status
Peer-reviewed
Abstract Read
~2 min
Abstract Words
348
Citations
N/A
Abstract
Dual-energy x-ray absorptiometry (DXA) is a well established technique for measuring bone mineral density (BMD). However, in recent years DXA is increasingly being used to measure body composition in terms of fat and fat-free mass. DXA scanners must also determine the soft tissue baseline value from soft-tissue-only regions adjacent to bone. The aim of this work is to determine, using computer simulations, the optimum x-ray energies for: a number of dose models, different tissues, i.e. bone mineral, average soft tissue, lean soft tissue and fat; and a range of anatomical sites and patient sizes. Three models for patient dose were evaluated: total beam energy, entrance exposure and absorbed dose calculated by Monte Carlo modelling. A range of tissue compositions and thicknesses were chosen to cover typical patient variations for the three sites: femoral neck, PA spine and lateral spine. In this work, the optimisation of the energies is based on: (1) the uncertainty that arises from the quantum statistical nature of the number of x-rays recorded by the detector, and (2) the radiation dose received by the patient. This study has deliberately not considered other parameters such as detector response, electronic noise, x-ray tube heat load etc, because these are technology dependent parameters, not ones that are inherent to the measuring technique. Optimisation of the energies is achieved by minimisation of the product of variance of density measurement and dose which is independent of the absolute intensities of the x-ray beams. The results obtained indicate that if solving for bone density, then Elow in the range 34 to 42 keV, Ehigh in the range 100 to 200 keV and incident intensity ratio (low energy/high energy) in the range 3 to 10 is a reasonable compromise for the normal range of patient sizes. The choice of energies is complicated by the fact that the DXA unit must also solve for fat and lean soft tissue in soft-tissue-only regions adjacent to the bone. In this case the ranges of energies suggested above are acceptable only for the average phantom. In extreme cases the variance-dose product can be up to 50 times higher than for the ideal energies.
Why This Paper Matters
- This paper contributes to the Quantum Simulation research area in the Quantum Articles archive.
- It adds a 1999 reference point for readers tracking recent quantum research.
- Dual-energy x-ray absorptiometry (DXA) is a well established technique for measuring bone mineral density (BMD).
Paper Tools
Become a member to use research tools
Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.
Publisher Share
Cite This Paper
Copy URL
Compare
Copy DOI Add to Reading List
Category Correction Request
Category Correction Request
Help us improve classification quality by proposing a better category. Every request is reviewed by an admin.
Sign in to submit a category correction request for this paper.
Log In to SubmitReferences & Citation Signals
Community Reactions
Quick sentiment from readers on this paper.
Score:
0
Likes: 0
Dislikes: 0
Sign in to react to this paper.
Discussion & Reviews (Moderated)
Average Rating: 0.0 / 5 (0 ratings)
No written reviews yet.