Quick Navigation

Topics

Quantum Chemistry Spin Qubits Silicon Quantum Computing Quantum Device Fabrication Process Engineering Quantum Simulation

Measurement of fluorophore concentrations and fluorescence quantum yield in tissue-simulating phantoms using three diffusion models of steady-state spatially resolved fluorescence.

PubMed
Authors: Diamond KR, Farrell TJ, Patterson MS

Year

2003

Paper ID

12970

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

283

Citations

40

Abstract

Steady-state diffusion theory models of fluorescence in tissue have been investigated for recovering fluorophore concentrations and fluorescence quantum yield. Spatially resolved fluorescence, excitation and emission reflectance Carlo simulations, and measured using a multi-fibre probe on tissue-simulating phantoms containing either aluminium phthalocyanine tetrasulfonate (AlPcS4), Photofrin meso-tetra-(4-sulfonatophenyl)-porphine dihydrochloride The accuracy of the fluorophore concentration and fluorescence quantum yield recovered by three different models of spatially resolved fluorescence were compared. The models were based on: (a) weighted difference of the excitation and emission reflectance, (b) fluorescence due to a point excitation source or (c) fluorescence due to a pencil beam excitation source. When literature values for the fluorescence quantum yield were used for each of the fluorophores, the fluorophore absorption coefficient (and hence concentration) at the excitation wavelength (mu(a,x,f)) was recovered with a root-mean-square accuracy of 11.4% using the point source model of fluorescence and 8.0% using the more complicated pencil beam excitation model. The accuracy was calculated over a broad range of optical properties and fluorophore concentrations. The weighted difference of reflectance model performed poorly, with a root-mean-square error in concentration of about 50%. Monte Carlo simulations suggest that there are some situations where the weighted difference of reflectance is as accurate as the other two models, although this was not confirmed experimentally. Estimates of the fluorescence quantum yield in multiple scattering media were also made by determining mu(a,x,f) independently from the fitted absorption spectrum and applying the various diffusion theory models. The fluorescence quantum yields for AlPcS4 and TPPS4 were calculated to be 0.59 +/- 0.03 and 0.121 +/- 0.001 respectively using the point source model, and 0.63 +/- 0.03 and 0.129 +/- 0.002 using the pencil beam excitation model. These results are consistent with published values.

Why This Paper Matters

  • This paper contributes to the Quantum Simulation research area in the Quantum Articles archive.
  • It adds a 2003 reference point for readers tracking recent quantum research.
  • Steady-state diffusion theory models of fluorescence in tissue have been investigated for recovering fluorophore concentrations and fluorescence quantum yield.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #12970 #78797 Local polarization control of o... #78792 Demonstration of subspace-searc... #78846 Analog quantum simulation of Sh... #78837 TLS loss in superconducting res...

External citation index: OpenAlex citation signal • updated 2026-10-22 22:34:06

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.