Quick Navigation

Topics

Spin Qubits Silicon Quantum Computing Quantum Chemistry Quantum Simulation Quantum Foundations

Triple-quantum-filtered sodium imaging of the human brain at 4.7 T.

PubMed
Authors: Tsang A, Stobbe RW, Beaulieu C

Year

2012

Paper ID

12216

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

193

Citations

35

Abstract

The limited signal-to-noise ratio of triple-quantum-filtered MRI of sodium is a major hurdle for its application clinically. Although it has been shown that short 90° radiofrequency pulses in combination with sufficiently long repetition time for full T(1) recovery (labelled "standard" parameters) produce the maximum signal through the triple-quantum-filter, and in this work, simulation and images of agar phantoms and human brain demonstrate that the use of longer radiofrequency pulses and reduced repetition time (optimized parameters to accommodate more averages for a constant specific absorption rate, reducing noise variance for a given scan length) results in signal-to-noise ratio improvement (22 ± 5% in brain tissue of five healthy volunteers--images created in 11 min with nominal resolution of 8.4 mm isotropic). However, residual intensity was observed in the ventricular space on triple-quantum-filtered images acquired with either optimized or standard parameters, contrary to the expectation of complete single-quantum signal suppression. Further simulation and experimentation suggest that this is likely due to the combination of triple-quantum-passed signal from surrounding brain tissue being spatially smeared into the ventricular space and single-quantum-signal breakthrough from sodium nuclei in the fluid space. It is shown that the latter can be eliminated with judicious first flip angle selection.

Why This Paper Matters

  • This paper contributes to the Quantum Simulation research area in the Quantum Articles archive.
  • It adds a 2012 reference point for readers tracking recent quantum research.
  • The limited signal-to-noise ratio of triple-quantum-filtered MRI of sodium is a major hurdle for its application clinically.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #12216 #68971 On solutions of the Schrödinger... #69042 Simultaneous Fragment Docking f... #69041 Multi-modes Bessel-Gaussian-Orb... #69040 Collective Emission in LH2 Asse...

External citation index: OpenAlex citation signal • updated 2026-06-19 14:25:27

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.