You're viewing papers too quickly. Please wait a moment.<br>This helps keep the archive available for everyone.

Quick Navigation

Topics

Quantum Measurement State Discrimination Quantum Sensing Metrology Qubit Coherence Noise Stability Characterization

Influence of spill-over for (99m)Tc images and the effect of scatter correction for dual-isotope simultaneous acquisition with (99m)Tc and (18)F using small-animal SPECT-PET/CT system.

PubMed
Authors: Shibutani T, Onoguchi M, Kanno T, Kinuya S

Year

2024

Paper ID

9432

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

235

Citations

2

Abstract

A dual-isotope simultaneous acquisition (DISA) of Tc and F affects the image quality of Tc by crosstalk and spill-over from F. We demonstrated the influence of spill-over and crosstalk on image quality and its correction effect for DISA SPECT with Tc and F. A fillable cylindrical chamber of 30 mm with NEMA-NU4 image quality phantom was filled with Tc only or a mixed Tc and F solution (C). Two small-region chambers were filled with Tc only or a mixed Tc and F solution made at half the radioactivity concentration of C (C) and non-radioactive water (C). The F/Tc ratio for DISA was set at approximately 0.4-12. Two types of Tc transverse images with and without scatter correction (SC and nonSC) were created. The Tc images of single-isotope acquisition (SIA) were created as a reference. The DISA/SIA ratio and contrast of Tc were compared between SIA and DISA. Although the DISA/SIA ratios with nonSC of C, C and C gradually increased with increasing FTc ratio, it was nearly constant by SC. The contrasts of C and C were similar to a reference value for both nonSC and SC. In conclusion, DISA images showed lower image quality as the F/Tc ratio increased. The image quality in hot-spot regions such as C and C was improved by SC, whereas cold-spot regions such as C could not completely remove the influence of spill-over even with SC.

Why This Paper Matters

  • This paper contributes to the Quantum Sensing & Metrology research area in the Quantum Articles archive.
  • It adds a 2024 reference point for readers tracking recent quantum research.
  • A dual-isotope simultaneous acquisition (DISA) of Tc and F affects the image quality of Tc by crosstalk and spill-over from F.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #9432

External citation index: OpenAlex citation signal • updated 2026-06-15 08:44:02

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.