Quick Navigation
Topics
Quantum Networks
Deep-learning denoising for ultrahigh-resolution photon-counting detector CT: phantom and in vivo evaluation of non-calcified coronary plaques.
PubMed
Authors: Hyska S, Hagar MT, Osoria-Velasquez J, Fink N, Ricke J, Halfmann MC, Marques H, McVeigh E, Wesbey G, Maurovich-Horvat P, Szilveszter B, Emrich T, Varga-Szemes A, Vecsey-Nagy M
Year
2026
Paper ID
72083
Status
Peer-reviewed
Abstract Read
~2 min
Abstract Words
238
Citations
N/A
Abstract
To assess the value of convolutional neural network (CNN)-based denoising for the evaluation of non-calcified coronary plaques on ultrahigh-resolution (UHR) photon-counting detector (PCD) coronary CT angiography (CCTA). A dynamic phantom containing lipid-rich and fibrotic plaques with 50%-diameter stenosis (PDS) was scanned on PCD-CT under varying conditions. For in-vivo imaging, consecutive patients with non-calcified coronary plaques (NCPs) who underwent CCTA with PCD-CT were included. Image series were reconstructed using a sharp vascular kernel (Bv64) with slice thicknesses of 0.2 mm/0.4 mm, quantum iterative reconstruction (QIR) levels 3/4, and with/without CNN denoising. Phantom-based line-profile analysis yielded edge-width at half maximum (EWHM) and 10-90% rise distance as sharpness metrics. Plaque contrast-to-noise ratio (CNR) and PDS were assessed in the phantom and in patients. Two readers evaluated subjective image quality (noise, diagnostic confidence) using a four-point Likert scale. Pairwise comparisons were performed using a Bonferroni-corrected p < 0.002 for significance. Fifty-five patients (median age 74 [66.5-78] years; 19 women) with 97 NCPs were included. Phantom-based sharpness metrics remained unchanged after denoising (all pairwise p > 0.051). CNN denoising increased plaque CNR consistently in the phantom (fibrotic: 0.80-1.64 to 0.92-2.06; lipid-rich: 0.21-0.34 to 0.35-0.46) and in vivo (0.99-2.07 to 1.37-2.92, all pairwise p < 0.001). Denoising did not alter PDS values in phantom or in vivo plaques (all pairwise p > 0.006). Subjective image noise and diagnostic confidence improved across all reconstructions (all pairwise p < 0.001). CNN-based denoising of UHR PCD-CT improves image quality of non-calcified coronary plaques, while preserving sharpness and quantitative stenosis metrics.
Why This Paper Matters
- This paper contributes to the Quantum Networks research area in the Quantum Articles archive.
- It adds a 2026 reference point for readers tracking recent quantum research.
- To assess the value of convolutional neural network (CNN)-based denoising for the evaluation of non-calcified coronary plaques on ultrahigh-resolution (UHR) photon-counting...
Paper Tools
Become a member to use research tools
Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.
Publisher Share
Cite This Paper
Copy URL
Compare
Copy DOI Add to Reading List
Category Correction Request
Category Correction Request
Help us improve classification quality by proposing a better category. Every request is reviewed by an admin.
Sign in to submit a category correction request for this paper.
Log In to SubmitReferences & Citation Signals
Community Reactions
Quick sentiment from readers on this paper.
Score:
0
Likes: 0
Dislikes: 0
Sign in to react to this paper.
Discussion & Reviews (Moderated)
Average Rating: 0.0 / 5 (0 ratings)
No written reviews yet.