Quick Navigation

Topics

Trapped Ion Quantum Computing

Device-Agnostic Microwave Noise Metrology for Nonlinear Cryogenic Quantum Devices

arXiv
Authors: Andrea Celotto, Alessandro Alocco, Bernardo Galvano, Luca Fasolo, Emanuele Palumbo, Luca Callegaro, Luca Oberto, Patrizia Livreri, Emanuele Enrico

Year

2026

Paper ID

68153

Status

Preprint

Abstract Read

~2 min

Abstract Words

250

Citations

N/A

Abstract

Microwave devices capable of near-quantum-limited signal processing are essential components in the toolbox of solid-state quantum technologies. The manipulation and readout of single-photon microwave signals through amplifiers, mixers, isolators, etc. must fulfill strict requirements in terms of signal integrity to ensure reliable operation. These active microwave quantum devices operate in complex cryo-electronic setups. This poses challenges to their characterization, since all relevant figures of merit must be expressed at the reference planes of their ports. Even though cryogenic S-parameter calibration is non-trivial, metrological approaches are converging toward rigorous methods. Furthermore, preserving signal integrity must be quantified via absolute noise levels at the ports of the Device Under Test (DUT), requiring an absolute power reference. In this work, we present an in situ noise metrology protocol based on substituting a controllable noise source for the DUT. We motivate this choice by showing that placing the noise source at the DUT input impacts the separability of the calibration from the DUT characteristics. Our proposed architecture combines Planck spectroscopy using a Variable Temperature Stage with Short-Open-Load-Reciprocal scattering-parameter calibration, so that noise and scattering quantities are referred to the same cryogenic reference planes. In this configuration, the readout-chain calibration is separated from the internal dynamics of the DUT. As a demanding use case, we apply the protocol to a Josephson Traveling Wave Parametric Amplifier and extract its gain and input-referred added noise under pump conditions activating multimode nonlinear behavior. This illustrates how our device-agnostic protocol supports portable noise characterization of nonlinear cryogenic microwave devices.

Why This Paper Matters

  • This paper contributes to the Trapped-Ion Quantum Computing research area in the Quantum Articles archive.
  • It adds a 2026 reference point for readers tracking recent quantum research.
  • Microwave devices capable of near-quantum-limited signal processing are essential components in the toolbox of solid-state quantum technologies.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Show Paper arXiv Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #68153 #69039 SAT, MaxSAT, and SMT for QLDPC ... #69038 Physically Constrained Ensemble... #69023 Scalable Quantum Algorithms for... #69016 Solution of the Equation-of-Mot...

External citation index: OpenAlex citation signal

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.