Quick Navigation

Topics

Quantum Algorithms

Squeezed state degradations due to mode mismatch and thermal aberrations in gravitational wave detectors

arXiv
Authors: Kevin Kuns, Daniel Brown

Year

2026

Paper ID

56791

Status

Preprint

Abstract Read

~2 min

Abstract Words

257

Citations

N/A

Abstract

To date, frequency-dependent squeezed light has been used to reduce quantum noise in interferometric gravitational wave detectors by 6.1 dB (a factor of two). Future upgrades and detectors aim to both reduce quantum noise by 10 dB (a factor of three) and to increase the circulating power in the interferometer arm cavities. Achieving these goals will be extremely challenging due, in part, to the degradations to the squeezed state caused by mode mismatch between the internal interferometer optical cavities and between the auxiliary external cavities. It is therefore imperative to gain a detailed understanding of all sources of mismatch and to obtain experience in mitigating their effects in the current detectors in order to improve astrophysical sensitivity now and in the future. Two types of internal mismatch are identified which are due to the thermal aberrations generated when the test mass optics absorb a small fraction of the circulating arm power. It is found that the dynamics responsible for the degradations caused by the mismatch between the quadratic part of the wavefront of two modes has a characteristic low-pass frequency dependence while the dynamics of the mismatch due to all higher order thermal aberrations has a high-pass behavior. As a consequence, the two types of mismatch are predominantly responsible for different squeezing degradations - some of which are significant for the current detectors and some of which will only be important for future detectors with longer arms. The behavior of these two types of internal mismatch are described and the implications for detector design, operation, and characterization are discussed.

Why This Paper Matters

  • It adds a 2026 reference point for readers tracking recent quantum research.
  • To date, frequency-dependent squeezed light has been used to reduce quantum noise in interferometric gravitational wave detectors by 6.1 dB (a factor of two).

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Show Paper arXiv Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #56791 #78853 When irrelevance governs: dissi... #78852 Quantum Information-Theoretic A... #78851 Quantum-assisted rendezvous on ... #78850 An Instability of the Quantum M...

External citation index: OpenAlex citation signal

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.