Quick Navigation

Topics

Quantum State Preparation Representation Quantum Device Fabrication Process Engineering Quantum Chemistry Entanglement Theory Quantum Correlations

Precision measurement of radioactivity in gamma-rays spectrometry using two HPGe detectors (BEGe-6530 and GC0818-7600SL models) comparison techniques: Application to the soil measurement

DOAJ
Authors: Guembou Shouop Cebastien Joel, Samafou Penabei, Moyo Maurice Ndontchueng, Gregoire Chene, Eric Jilbert Nguelem Mekontso, Alexandre Ngwa Ebongue, Motapon Ousmanou, Strivay David

Year

2017

Paper ID

45282

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

280

Citations

42

Abstract

To obtain high quality of results in gamma spectrometry, it is necessary to select the best HPGe detector for particular measurements, to calibrate energy and efficiency of gamma detector as accurate as possible. To achieve this aim, the convenient detector model and gamma source can be very useful. The purpose of this study was to evaluate the soil specific activity using two HPGe model (BEGe-6530 and GC0818-7600SL) by comparing the results of the two detectors and the technics used according to the detector type. The relative uncertainty activity concentration was calculated for 226Ra, 232Th and 40K. For broad energy germanium detector, BEGe-6530, the relative uncertainty concentration ranged from 2.85 to 3.09% with a mean of 2.99% for 226Ra, from 2.29 to 2.49% with a means of 2.36% for 232Th and from 3.47 to 22.37% with a mean of 12.52% for 40K. For GC0818-7600SL detector, it was ranged from 10.45 to 25.55% with a mean of 17.10% for 226Ra, from 2.54 to 3.56% with a means of 3.10% for 232Th and from 3.42 to 7.65% with a mean of 5.58% for 40K. The average report between GC0818-7600SL model and BEGe-6530 model was calculated and showed the mean value of 3.36. The main study was based on the following points: • Determination of The relative uncertainty activity concentration of 226Ra, 232Th and 40K • Determination of the relative uncertainty related to the radium equivalent activity to compare the performance of the two detection systems • Proved that the activity concentration determination in gamma spectrometry depended on the energy range emitted by a radionuclide. This study showed that the standard deviation measurement was less important to the result realized with BEGe-6530 HPGe model. Our findings were demonstrated that the results of the Broad Energy Germanium detector were more reliable.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #45282 #67310 Women for Quantum -- Manifesto ... #67361 The Channel Capacity of a Relat... #67349 Spectral radii for subsets of H... #67340 Ultra-sensitive solid-state org...

External citation index: OpenAlex citation signal • updated 2026-06-04 03:55:07

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.