Quick Navigation

Topics

Trapped Ion Quantum Computing Superconducting Qubits

Investigation of Magnetoelectric Sensor Requirements for Deep Brain Stimulation Electrode Localization and Rotational Orientation Detection

DOAJ
Authors: Mevlüt Yalaz, Günther Deuschl, Markus Butz, Alfons Schnitzler, Ann-Kristin Helmers, Michael Höft

Year

2021

Paper ID

28291

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

309

Citations

7

Abstract

Correct position and orientation of a directional deep brain stimulation (DBS) electrode in the patient’s brain must be known to fully exploit its benefit in guiding stimulation programming. Magnetoelectric (ME) sensors can play a critical role here. The aim of this study was to determine the minimum required limit of detection (LOD) of a ME sensor that can be used for this application by measuring the magnetic field induced by DBS. For this experiment, a commercial DBS system was integrated into a head phantom and placed inside of a state-of-the-art Superconducting Quantum Interference Device (SQUID)-based magnetoencephalography system. Measurements were performed and analyzed with digital signal processing. Investigations have shown that the minimum required detection limit depends on various factors such as: measurement distance to electrode, bandwidth of magnetic sensor, stimulation amplitude, stimulation pulse width, and measurement duration. For a sensor that detects only a single DBS frequency (stimulation frequency or its harmonics), a LOD of at least 0.04 pT/Hz<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mrow></mrow><mrow><mn>0.5</mn></mrow></msup></semantics></math></inline-formula> is required for 3 mA stimulation amplitude and 60 <inline-formula>μ<math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mi mathvariant="sans-serif">μ</mi></semantics></math></inline-formula>s pulse width. This LOD value increases by an order of magnitude to 0.4 pT/Hz<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mrow></mrow><mrow><mn>0.5</mn></mrow></msup></semantics></math></inline-formula> for a 1 kHz, and by approximately two orders to 3 pT/Hz<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mrow></mrow><mrow><mn>0.5</mn></mrow></msup></semantics></math></inline-formula> for a 10 kHz sensor bandwidth. By averaging, the LOD can be reduced by at least another 2 orders of magnitude with a measurement duration of a few minutes.

Why This Paper Matters

  • This paper contributes to the Superconducting Qubits research area in the Quantum Articles archive.
  • It adds a 2021 reference point for readers tracking recent quantum research.
  • Correct position and orientation of a directional deep brain stimulation (DBS) electrode in the patient’s brain must be known to fully exploit its benefit in guiding...

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #28291 #78837 TLS loss in superconducting res... #78829 Graphene double quantum dot as ... #78817 Modelling Josephson Junctions w... #78809 A quasiparticle-protected super...

External citation index: OpenAlex citation signal • updated 2026-10-21 22:25:36

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.