Quick Navigation

Topics

Quantum Sensing Metrology

Single cell magnetometry by magnetophoresis vs. bulk cell suspension magnetometry by SQUID-MPMS - a comparison.

PubMed
Authors: Xue W, Moore LR, Nakano N, Chalmers JJ, Zborowski M

Year

2019

Paper ID

1643

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

246

Citations

0

Abstract

Paramagnetic constituents of a cell have strong effect on cell's volume magnetic susceptibility even at low volume fraction because of their high susceptibility relative to that of the diamagnetic cell constituents. The effect can be measured at a single cell level by measuring cell terminal velocity in viscous media using a microscope equipped with a well-defined field and gradient magnet configuration (referred to as magnetophoretic analysis by cell tracking velocimetry, CTV). The sensitivity of such a microscopic-scale magnetometry was compared to that of a reference method of superconducting quantum interference-magnetic properties measurement system (SQUID-MPMS) using a red blood cell (RBC) suspension model. The RBC hemoglobin oxygen saturation determines the hemoglobin molecular magnetic susceptibility (diamagnetic when fully oxygenated, paramagnetic when fully deoxygenated or converted to methemoglobin). The SQUID-MPMS measurements were performed on an average of 5,000 RBCs in 20 μL physiological phosphate buffer at room temperature, those by CTV on a single cell track in a mean magnetic field of 1.6 T and mean gradient of 240 T/m, repeated for an average of 1,000 tracks per sample. This suggests 5,000× higher sensitivity of cell susceptometry by magnetophoretic analysis than by SQUID-MPMS. The magnetophoretic mean RBC magnetic susceptibilities were in the range determined by SQUID-MPMS (lower limit) and theory (upper limit). The ability of magnetophoretic analysis to resolve susceptibility peaks in a mixed cell populations was confirmed for an oxy RBC and met RBC mixture. Magnetophoretic analysis by CTV provides new tool for studies of emergence of paramagnetic reaction products in the cell.

Why This Paper Matters

  • This paper contributes to the Quantum Sensing & Metrology research area in the Quantum Articles archive.
  • It adds a 2019 reference point for readers tracking recent quantum research.
  • Paramagnetic constituents of a cell have strong effect on cell's volume magnetic susceptibility even at low volume fraction because of their high susceptibility relative to...

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #1643

External citation index: OpenAlex citation signal • updated 2026-06-14 03:11:05

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.