Quick Navigation

Topics

Trapped Ion Quantum Computing

High-Resolution X-ray Spectroscopy Close to Room Temperature.

PubMed
Authors: Strüder L, Meidinger N, Stotter D, Kemmer J, Lechner P, Leutenegger P, Soltau H, Eggert F, Rohde M, Schulein T

Year

1998

Paper ID

13489

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

283

Citations

66

Abstract

: Originally designed as position-sensitive detectors for particle tracking, silicon drift detectors (SDDs) are now used for high-count rate X-ray spectroscopy, operating close to room temperature. Their low-capacitance read-node concept places them among the fastest high-resolution detector systems. They have been used in a new spectrum of experiments in the wide field of X-ray spectroscopy: fluorescent analysis, diffractometry, materials analysis, and synchrotron experiments such as X-ray holography and element imaging in scanning electron microscopes. The fact that the detector system can be used at room temperature with good spectroscopic performance and at -10 degrees C with excellent energy resolution, avoiding liquid nitrogen for cooling and high-quality vacuum, guarantees a large variety of new applications, independent of the laboratory environment. A brief description of the device principles is followed by basics on low noise amplification. The performance results of a complete detector system are presented as well as some dedicated applications already realized, including use in a surface mapping instrument and use of a "mini-spectrometer" for the analysis of works of art. Fully depleted pn-charge-coupled devices (pn-CCDs) have been fabricated for the European X-ray Multi-Mirror mission (XMM) and the German X-ray satellite ABRIXAS, enabling high-speed, low-noise, position-resolving X-ray spectroscopy. The detector was designed and fabricated with a homogeneously sensitive area of 36 cm2. At -70 degrees C it has a noise of 4 e- rms, with a readout time of the total focal plane array of 4 msec. The maximum count rate for single photon counting was 10(5) cps under flat field conditions. In the integration mode, more than 10(9) cps can be detected at 6 keV. Its position resolution is on the order of 100 µm. The quantum efficiency is higher than 90%, ranging from carbon K X-rays (277 eV) up to 10 keV.

Why This Paper Matters

  • This paper contributes to the Trapped-Ion Quantum Computing research area in the Quantum Articles archive.
  • It adds a 1998 reference point for readers tracking recent quantum research.
  • : Originally designed as position-sensitive detectors for particle tracking, silicon drift detectors (SDDs) are now used for high-count rate X-ray spectroscopy, operating close...

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #13489

External citation index: OpenAlex citation signal • updated 2026-11-02 12:09:19

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.