Quick Navigation

Topics

Spin Qubits Silicon Quantum Computing Superconducting Qubits Open Quantum Systems Decoherence Quantum Chemistry

Analysis of the detective quantum efficiency of a developmental detector for digital mammography.

PubMed
Authors: Williams MB, Simoni PU, Smilowitz L, Stanton M, Phillips W, Stewart A

Year

1999

Paper ID

13421

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

294

Citations

73

Abstract

We are developing a modular detector for applications in full field digital mammography and for diagnostic breast imaging. The detector is based on a design that has been refined over the past decade for applications in x-ray crystallography [Kalata et al., Proc. SPIE 1345, 270-279 (1990); Phillips et al. ibid. 2009, 133-138 (1993), Phillips et al., Nucl. Instrum. Methods Phys. Rev. A 334, 621-630 (1993)]. The full field mammographic detector, currently undergoing clinical evaluation, is formed from a 19 cm x 28 cm phosphor screen, read out by a 2 x 3 array of butted charge-coupled device (CCD) modules. Each 2k x 2k CCD is optically coupled to the phosphor via a fiber optic taper with dimensions of 9.4 cm x 9.4cm at the phosphor. This paper describes the imaging performance of a two-module prototype, built using a similar design. In this paper we use cascaded linear systems analysis to develop a model for calculating the spatial frequency dependent noise power spectrum (NPS) and detective quantum efficiency (DQE) of the detector using the measured modulation transfer function (MTF). We compare results of the calculation with the measured NPS and DQE of the prototype. Calculated and measured DQEs are compared over a range of clinically relevant x-ray exposures and kVps. We find that for x-ray photon energies between 10 and 28 keV, the detector gain ranges between 2.5 and 3.7 CCD electrons per incident x-ray, or approximately 5-8 electrons per absorbed x ray. Using a Mo/Mo beam and acrylic phantom, over a detector entrance exposure range of approximately 10 to 80 mR, the volume under the measured 2-d NPS of the prototype detector is proportional to the x-ray exposure, indicating quantum limited performance. Substantial agreement between the calculated and measured values was obtained for the frequency and exposure dependent NPS and DQE over a range of tube voltage from 25 to 30 kVp.

Why This Paper Matters

  • This paper contributes to the Quantum Chemistry research area in the Quantum Articles archive.
  • It adds a 1999 reference point for readers tracking recent quantum research.
  • We are developing a modular detector for applications in full field digital mammography and for diagnostic breast imaging.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #13421 #68437 Transition-state lattice modes ... #68449 Scale-Invariant Open Quantum Sy... #68470 A fluxonium qubit-based hybrid ... #68465 Bounding Eigenstate Overlap fro...

External citation index: OpenAlex citation signal • updated 2026-06-10 18:50:48

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.