Quick Navigation

Topics

Spin Qubits Silicon Quantum Computing Superconducting Qubits

Detection of bacteria in suspension by using a superconducting quantum interference device.

PubMed
Authors: Grossman HL, Myers WR, Vreeland VJ, Bruehl R, Alper MD, Bertozzi CR, Clarke J

Year

2004

Paper ID

12941

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

199

Citations

193

Abstract

We demonstrate a technique for detecting magnetically labeled Listeria monocytogenes and for measuring the binding rate between antibody-linked magnetic particles and bacteria. This sensitive assay quantifies specific bacteria in a sample without the need to immobilize them or wash away unbound magnetic particles. In the measurement, we add 50-nm-diameter superparamagnetic magnetite particles, coated with antibodies, to an aqueous sample containing L. monocytogenes. We apply a pulsed magnetic field to align the magnetic dipole moments and use a high-transition temperature superconducting quantum interference device, an extremely sensitive detector of magnetic flux, to measure the magnetic relaxation signal when the field is turned off. Unbound particles randomize direction by Brownian rotation too quickly to be detected. In contrast, particles bound to L. monocytogenes are effectively immobilized and relax in about 1 s by rotation of the internal dipole moment. This Néel relaxation process is detected by the superconducting quantum interference device. The measurements indicate a detection limit of (5.6 +/- 1.1) x 10(6) L. monocytogenes in our sample volume of 20 microl. If the sample volume were reduced to 1 nl, we estimate that the detection limit could be improved to 230 +/- 40 L. monocytogenes cells. Time-resolved measurements yield the binding rate between the particles and bacteria.

Why This Paper Matters

  • This paper contributes to the Superconducting Qubits research area in the Quantum Articles archive.
  • It adds a 2004 reference point for readers tracking recent quantum research.
  • We demonstrate a technique for detecting magnetically labeled Listeria monocytogenes and for measuring the binding rate between antibody-linked magnetic particles and bacteria.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #12941 #78837 TLS loss in superconducting res... #78829 Graphene double quantum dot as ... #78817 Modelling Josephson Junctions w... #78809 A quasiparticle-protected super...

External citation index: OpenAlex citation signal • updated 2026-10-22 13:49:24

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.