Quick Navigation
Topics
Benchmarking Verification Validation
Reaching the quantum noise limit for interferometric measurement of optical nonlinearity in vacuum
arXiv
Authors: Ali Aras, Adrien E. Kraych, Xavier Sarazin, Elsa Baynard, François Couchot, Moana Pittman
Year
2026
Paper ID
125
Status
Preprint
Abstract Read
~2 min
Abstract Words
191
Citations
N/A
Abstract
Quantum Electrodynamics predicts that the vacuum must behave as a nonlinear optical medium:the vacuum optical index should increase when vacuum is stressed by intense electromagnetic fields.The DeLLight (Deflection of Light by Light) project aims to measure it by using intense and ultra-short laser pulses delivered by the LASERIX facility at IJCLab (Paris-Saclay University). Theprinciple is to measure by interferometry the deflection of a low-intensity probe pulse when crossingthe vacuum optical index gradient produced by an external high-intensity pump pulse. The detectionof the expected signal requires measuring the position of the interference intensity profile with a highspatial resolution, limited by the ultimate quantum noise. However, the spatial resolution is highlydegraded by the phase noise induced by the mechanical vibrations of the interferometer. In order tosuppress this interferometric phase noise, we have developed a new method, named High-FrequencyPhase Noise Suppression (HFPNS) method, based on the use of a delayed reference signal to correctany noise-related signal appearing in the probe beam. In this work, we present the experimentalvalidation of this novel method. The results demonstrate a robust path toward picometer-scalesensitivity and provide a key step toward the observation of QED-induced vacuum refraction.
Why This Paper Matters
- This paper contributes to the Benchmarking, Verification & Validation research area in the Quantum Articles archive.
- It adds a 2026 reference point for readers tracking recent quantum research.
- Quantum Electrodynamics predicts that the vacuum must behave as a nonlinear optical medium:the vacuum optical index should increase when vacuum is stressed by intense...
Paper Tools
Become a member to use research tools
Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.
Show Paper arXiv Publisher Share
Cite This Paper
Copy URL
Compare
Copy DOI Add to Reading List
Category Correction Request
Category Correction Request
Help us improve classification quality by proposing a better category. Every request is reviewed by an admin.
Sign in to submit a category correction request for this paper.
Log In to SubmitReferences & Citation Signals
Community Reactions
Quick sentiment from readers on this paper.
Score:
0
Likes: 0
Dislikes: 0
Sign in to react to this paper.
Discussion & Reviews (Moderated)
Average Rating: 0.0 / 5 (0 ratings)
No written reviews yet.