Quick Navigation

Topics

Spin Qubits Silicon Quantum Computing Quantum Simulation

A gallium arsenide hybrid-pixel counting detector for 100 keV cryo-electron microscopy.

PubMed
Authors: Zambon P, Montemurro GV, Fernandez-Perez S, Schnyder R, Lehmann N, Sakhelashvili T, Burkhalter S, Meffert M, Jensen A, Würsch P, Jud PA, Dudina A, Kaspar S, Schulze-Briese C

Year

2026

Paper ID

10062

Status

Peer-reviewed

Abstract Read

~2 min

Abstract Words

163

Citations

0

Abstract

The recent interest in 100 keV cryo-electron microscopy has created a demand for specialized detectors that maximize information per unit dose while remaining cost-effective. We present a hybrid-pixel electron counting detector system tailored for cryo-electron microscopy applications using 100 keV electron energy. The demonstrator uses a 500 μm-thick, chromium-compensated gallium arsenide (high-Z) sensor with a 36 μm pixel pitch arranged in a seamless 1266 × 1057 matrix. Its low-noise front-end electronics achieve a threshold energy as low as 2.5 keV and include an in-pixel hit digitization mechanism. The matrix is read out at a speed of 7.2 kfps and has a counter depth of 1 bit, allowing for an incoming rate of 28 e/s/pix at 5% coincidence loss. The imaging performance is evaluated in standard counting and super-resolution acquisition modes. Thanks to a custom-developed super-resolution algorithm, the detective quantum efficiency at zero-frequency amounts to 0.96 and at the physical Nyquist frequency to 0.56, resulting in an effective pixel size of 27.5 μm. Experimental data are complemented and critically compared with Monte Carlo simulations and analytical models.

Why This Paper Matters

  • This paper contributes to the Quantum Simulation research area in the Quantum Articles archive.
  • It adds a 2026 reference point for readers tracking recent quantum research.
  • The recent interest in 100 keV cryo-electron microscopy has created a demand for specialized detectors that maximize information per unit dose while remaining cost-effective.

Paper Tools

Become a member to use research tools

Sign in to open papers, visit source links, share, cite, compare, copy DOI links, request category corrections, and build your reading list.

Publisher Share Cite This Paper Copy URL Compare Copy DOI Add to Reading List Category Correction Request

References & Citation Signals

Local Citation Graph (Related-Paper Links)

Current Paper #10062 #69041 Multi-modes Bessel-Gaussian-Orb... #69040 Collective Emission in LH2 Asse... #69038 Physically Constrained Ensemble... #69034 Hardware-aware Low-latency Quan...

External citation index: OpenAlex citation signal • updated 2026-06-13 22:33:03

Community Reactions

Quick sentiment from readers on this paper.

Score: 0
Likes: 0 Dislikes: 0

Sign in to react to this paper.

Discussion & Reviews (Moderated)

Average Rating: 0.0 / 5 (0 ratings)

No written reviews yet.